Test for electricians. Find violations.

Today I want to move away from the usual "tips", "life hacks" and "homemade".

I recently had a coven ... It was necessary to help one company, eliminate the instructions of the inspector from the "energy supervision".

It seems to me, dear colleagues, that it will be interesting for you to play the role of an inspector yourself and find violations of the PB. And at the same time check whether your opinion agrees with the opinion of the inspector.

What violations the inspector found, I will describe in the comments. Until then, let's go!

  1. Main switchboard. There are 2 violations in this photo.

2. Again, the main switchboard. There is one violation here.

3. Switchboard workshop. To make it clearer to you, I marked the connection points of the input cable in the photo. 3 violations were found.

4. Ground bus in one of the workshops. One violation.

5. The same ground bus. One violation.

6. Switchboard of one of the workshops. Three violations.

What the inspector “dug up”, read below in the comments.

advertisement
admin

View Comments

  • What the inspector found:

    1. There is no introductory circuit breaker. External lighting is connected bypassing protection devices (white wire is connected to the bus before the disconnector on phase "A")
    2. The left circuit breaker with a rated current of 100A is connected to the busbar with conductors not designed for this load (aluminum 6mm2).
    3. There is no general circuit breaker. The discrepancy between the rated current of the third automaton on the left (32A) and the rated current of the outgoing cable. It is visually noticeable that the insulation of the third wire from the left is heated, which led to its darkening.
    4. Grounding leashes of different consumers are connected to the bus at one point.
    5. Grounding leashes are interconnected by means of twisting.
    6. There is no general circuit breaker. The neutral wires of different consumers are connected to the neutral bus using a common bolt. There is no protective cover on the front panel to prevent accidental contact with live parts.

Recent Posts

Washing machine drain pump repair and maintenance

Washing machine drain pump not working? Step by step instructions on how to fix it. Might not have to buy...

11 months ago

Simple car battery charger

A simple and reliable do-it-yourself car battery charger. Photo and Video Minimum details…

12 months ago

How to remove a stuck brake drum

How to remove a boiled, soured brake drum of Slavuta or Tavria

1 year ago

Homemade toys for children from the USSR

16 homemade products that were familiar to every child in the USSR. Toys of children of the USSR, which were made from ...

2 years ago

Repair of the lock and control board of the INDESIT washing machine or how I saved 6000 rubles

On self-repair, I saved about 6,000 rubles. Demonstrate how to quickly repair the lock of the washing machine ...

2 years ago

Why do you need to know the magnitude of the current kz

Why do you need to know the magnitude of the current kz? What is the use of this knowledge? Turns out to be very important...

2 years ago

This website uses cookies.

For any suggestions on the site: nsk-osb@cp9.ru